Performance test results for Anyfusion cartridge upgrade | |
---|---|
The existing drug injection pumps, the
infusion pump and the syringe pump, ensure accuracy for 2 hours. However,
recently, the nursing society recommends 96 hours of use without replacing the
set after setting once to prevent infection, and requires 96 hours of use in
all criminal records except NICU. Existing infusion pumps and syringe pumps
are inaccurate in real time for 96 hours due to structural problems of original
technology, and cannot be used by nurses in real time to manage controlled
average injection volume, and due to heavy labor and stress. Only Anyfusion's original technology can be
used without real-time verification and management. We are positively evaluated by producing
and supplying 10ml/hr of low-flow NICUs and Anyfusion cartridges, which are
replaced every 24 hours due to infection problems, and we are conducting demos
in many university hospitals NICUs as a reference. The NICU of some university hospitals who
have used Anyfusion is recommended, and for the PICU demo, the PICU and
previous department of the hospital requested 96 hours of use during the
product description. In response, some general hospitals who requested
Anyfusion purchase 96 hours to ensure real-time accuracy of ±0%, the results of
upgrading the cartridge are as follows.
1.
96-hour real-time ±0% accuracy
verification - Accurate injection of doctor's prescriptions based on medical
and clinical evidence to realize precision medical care.
2.
Verification of no air alarm in
most areas within the range adjustable to BBL (Bubble Level) 4 steps depending
on the size of air allowed for patients - 36 hours, 1 to 2 times in some areas
- Air alarm check by naturally generated air – Airless
3.
Verification of durability of
cartridge set that can be used for more than 100 hours The above verification was the most
stressful factor for drug injection nursing and medical staff around the world,
and since accurate and precise patient treatment was impossible, it was the
long-cherished desire of medical personnel, FDA, CE, and PMDA to solve this
problem. Infusion pumps are subject to excessive
stress by medical staff, nurses, and patients due to different inaccuracies and
frequent air alarms from tube manufacturers, and syringe pumps have a risk of
infection due to frequent replacement. In particular, inaccuracy and air alarm are
the most stressful and heavy work factors in patient-centered drug injection
nursing in the United States, Japan, and Germany. In most hospitals in Japan, separate
droppers are used due to infusion pump inaccuracy, and ICU medical, a major
U.S., can confirm on its website that it develops and uses a device that
collects air and removes it with a syringe. (Infusion therapy-IV system-Plum
360-Reduce the burden of IV pump alarms) Hospira, the predecessor of ICU medical,
was a company that consulted Anyfusion from 2014 to 2016 before it was merged
into Pfizer. We will actively utilize Anyfusion's
competitiveness as above and cooperate with major companies in strategic
cooperation and cooperation, and we will change the paradigm of the market by
revitalizing sales in the domestic market to become a game changer. Thank you. |